Specialized medical technology, clinical solutions and dependable support

Shielding Calculation & Facility Design

Professional radiation shielding calculation and facility planning services for radiology, nuclear medicine, radiotherapy, cyclotron, and other radiation-related installations. Support includes workload assessment, shielding design, room layout review, controlled and uncontrolled area evaluation, equipment positioning, and coordination with architectural and engineering requirements.

Professional radiation shielding calculation and facility planning services for radiology, nuclear medicine, radiotherapy, cyclotron, and other radiation-related installations, with support from concept development through final design review.

  • Workload Assessment – Evaluation of expected clinical workload, operating schedule, procedure type, patient throughput, source strength, beam energy, occupancy, and other parameters required for shielding design.

  • Radiation Source Characterization – Assessment of the radiation source, modality, beam quality, energy, use factor, directional workload, leakage, scatter, and other source-specific characteristics relevant to the facility.

  • Primary & Secondary Barrier Calculation – Determination of appropriate shielding requirements for primary barriers, secondary barriers, doors, ceilings, floors, maze structures, and penetrations.

  • Controlled & Uncontrolled Area Evaluation – Assessment of surrounding rooms and occupied spaces based on occupancy, area classification, applicable dose constraints, and expected radiation exposure.

  • Wall, Floor & Ceiling Shielding Design – Calculation of required thicknesses for concrete, lead, steel, high-density concrete, polyethylene, borated materials, or other suitable shielding materials depending on the radiation type.

  • Shielding for Radiotherapy Facilities – Design support for linear accelerator, stereotactic radiotherapy, brachytherapy, and other treatment facilities, including primary beam, leakage, scatter, door, maze, and roof considerations.

  • Cyclotron & PET Facility Shielding – Assessment of neutron and gamma shielding requirements for cyclotrons, target areas, radiochemistry spaces, hot labs, PET facilities, and associated controlled areas.

  • Nuclear Medicine & Theranostics Facility Design – Shielding assessment for hot labs, injection rooms, uptake rooms, gamma-camera/SPECT/PET areas, radionuclide therapy rooms, storage areas, waste rooms, and patient circulation zones.

  • Diagnostic Radiology Shielding – Shielding design for CT, X-ray, fluoroscopy, interventional radiology, mammography, and other diagnostic imaging installations.

  • Room Layout Review – Evaluation of room geometry, equipment orientation, beam direction, operator position, patient workflow, control-room location, adjacent occupancy, and access routes.

  • Equipment Positioning – Support in determining appropriate equipment location and orientation to improve shielding efficiency, clinical workflow, access, and serviceability.

  • Door & Maze Design – Assessment of radiation protection requirements for treatment-room entrances, maze geometry, shielded doors, neutron doors, and access-control arrangements where applicable.

  • Penetration & Service Duct Review – Evaluation of ducts, cable trays, conduits, ventilation penetrations, pipes, waveguides, and other openings that may affect shielding integrity.

  • Radiation Survey Planning – Preparation of measurement points and verification strategy for post-installation radiation surveys and shielding validation before clinical operation.

  • Dose Constraint Assessment – Application of appropriate design goals and dose limits for occupationally exposed workers, members of the public, controlled areas, and uncontrolled areas.

  • Shielding Optimization – Selection of practical shielding combinations to balance radiation safety, available space, structural load, construction feasibility, and project cost.

  • Architectural Coordination – Coordination with architects, civil engineers, structural engineers, MEP teams, equipment vendors, and contractors to integrate shielding requirements into the overall facility design.

  • Structural Load Consideration – Review of the additional structural burden created by heavy shielding materials, especially lead, steel, high-density concrete, and neutron shielding.

  • HVAC & Environmental Considerations – Coordination of ventilation, pressure relationships, cooling, heat load, air handling, and contamination-control requirements where relevant.

  • Regulatory Documentation Support – Preparation or review of technical shielding calculations, design reports, drawings, and supporting documentation required for institutional or regulatory submission.

  • Design Review & Verification – Independent review of architectural and shielding drawings before construction to identify gaps, conflicts, or unnecessary shielding.

  • As-Built Review – Comparison of completed construction with the approved shielding design to confirm that specified materials, thicknesses, and layouts have been implemented correctly.

  • Post-Installation Radiation Survey Support – Assistance with radiation measurements after equipment installation to verify shielding performance and confirm safe operation of the facility.

  • Future Expansion Planning – Consideration of potential increases in workload, equipment upgrades, higher-energy systems, or future clinical expansion so that the facility remains adaptable over time.

Need a quotation, demonstration or technical discussion?

Tell us what your hospital or department needs. We can route your enquiry to the relevant product or technical team.

WhatsApp